Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Journal of Jilin University(Medicine Edition) ; (6)2006.
Article in Chinese | WPRIM | ID: wpr-587047

ABSTRACT

Objective To identify the effect of insulin-like growth factor-1(IGF-1) gene transfer on motoneurons apoptosis in anterior horn after acute spinal cord injury in adult rats.Methods Thirty-six male Wistar rats were randomly divided into 3 groups: IGF-1 group,model group and control group.The SCI models were made by cutting half spinal cord of rats on the T_8 segment by ophthalmogy scissors.Lipofectamine and recombinant plasmid pcDNA-hIGF-1 complexes were injected into the injury spinal cord by microinjector in IGF-1 group while pcDNA3.1,LipfectAmine and saline were administered in model group.The expression of IGF1 was detected by immunohistochemistry method,the apoptosis of the motoneurons in anterior horn was detected by TUNEL,and moting function of hindlimbs was evaluated by BBB locomotor scale.Results Compared with model group and control group,the expression of IGF-1 was increased significantly(P

2.
Journal of Jilin University(Medicine Edition) ; (6)2006.
Article in Chinese | WPRIM | ID: wpr-586233

ABSTRACT

0.05).)Conclusion The extra-pedicular technique is feasible in biomechanics.

3.
Journal of Jilin University(Medicine Edition) ; (6)2006.
Article in Chinese | WPRIM | ID: wpr-594306

ABSTRACT

Objective To identify the effect of morphology of adult upper and middle thoracic pedicle on security of screw implantation.Methods Five fresh adult cadaveric thoracic spine from T1 to T8 were harvested.Pedicle transverse diameters were measured and compared with the smallest diameter(4.5 mm) of screw used in clinic.The screws were inserted and implant effect was observed.Results The mean transverse diameter of adult thoracic(T1-T8) were T1:4.74(3.85-5.25)mm,T2:4.51(3.45-5.25)mm,T3:4.15(3.60-4.65)mm,T4:3.75(3.10-4.50)mm,T5:4.25(3.70-4.65)mm,T6: 4.53(4.40-4.70)mm,T7:5.38(5.25-5.60)mm,T8:5.55(5.50-5.80)mm.Of all specimens,there were 9 specmen(22.5%) whose tranverse diameters were smaller than 4.5 mm.After implantation,two screws broke through pedicle lateral wall.Conclusion Adult pedicle transverse diameters in T3-T4 are smallest,transpedicular screw placement is difficult in some of these vertebrae,but in most of thoracic vertebrae,pedicle tranverse diameter could permit screw implanting in security.

SELECTION OF CITATIONS
SEARCH DETAIL